L*a*b* white paper, Illuminant D50, 45/0 geometry

Purpose of the test

This test is performed to determine the L*a*b* colour coördinates, using graphic arts spectrophotometers, of paper, solid board or folding board.

Procedure

Operate the instrument in accordance with ISO 13655 and the manufacturer’s instructions.

Leave the samples exposed for 24 h to 23°C and 50% R.H., according to ISO 187.

Each sample pack is made of a pad of paper to be tested and a coloured cover sheet.

Remove the coloured protective sheet from the test piece pad.

Place the test piece in the position indicated on the cover sheet on a black backing.

Without touching the test area use the procedure appropriate to the instrument to obtain t L*, a* and b* coordinates.

Report 10 measures of L*, a* and b*, their mean and standard deviation calculated to 3 significant figures.

ISO 13655
Nr. of samples

10 test pieces per level

Sample size 100 x 200 mm²

Specil size A4

Levels

L*:

Level 1: 90.0÷92.0

Level 2: 95.0÷97.0

Level 3: 87.0÷90.0

Level 4: 90.0÷92.0

a*:

Level 1: -0.6÷-0.5

Level 2: -1.0÷1.0

Level 3: 0.0÷2.0

Level 4: 1.0÷4.0

b*:

Level 1: 10.0÷11.0

Level 2: 3.0÷-4.0

Level 3: -2.0÷1.0

Level 4: -12.5÷-6.0

Reporting

Report 10 measures of L*, a*, and b*, their mean and their standard deviation. All to three significant digits.

CEPI test 6.12