TISSUE – RESIDUAL WATER ABSORPTION

Purpose of the test

This test is performed to determine the water absorption and absorption time of tissue paper.

Procedure

Operate the instrument in accordance with ISO 12625-8 (manual or automated method) and the manufacturer’s instructions.

From each stack, cut two test pieces of 76±1 mm width, with the length in machine direction (longer side of the specimen) to have a mass of 5,0±0,2 g.

Separate the sheets before testing.

Report 5 measures of absorption in g/g and absorption time in s, their mean and standard deviation calculated to 3 significant figures.

ISO 12625-8
Nr. of samples

3 stacks, containing 12 sheets for Level 1 and 9 sheets for Level 2

No special size

Levels

Capacity:

Level 1: 6.0÷9.0 g/g

Level 2: 14.0÷16.0 g/g

Time:

Level 1:  1.0÷3.0 s

Level 2: 2.0÷5.0 s

Reporting

Report 5valid results of measurements of both absorption in g/g and time in s, their mean and their standard deviation. All to three significant digits.

CEPI test 8.3