BASIS WEIGHT – GRAMMAGE

Purpose of the test

This test is performed to determine the weight in g/m² of paper, solid board or folding board.

Procedure

Operate the instrument in accordance with ISO 536 and the manufacturer’s instructions.

Leave the samples exposed for 24 h to 23°C and 50% R.H., according to ISO 187.

Check the zero setting of the balance.

Cut 20 test pieces to the required size.

Weigh each piece to your normal precision.

Report 20 measures in g/m², their mean and standard deviation calculated to 3 significant figures.

ISO 536
Nr. of samples

 

Cut 20 test pieces to the required size for Levels 1, 2 and 3 and at least 10, if possible 20 test pieces for Level 4.

Sample size Level 1-3: 150 x 150 mm²

Sample size Level 4: A5

Special size level 1-3: A4

Levels

Level 1: 55.0÷65.0 g/m²

Level 2: 85.0÷105 g/m²

Level 3: 270÷290 g/m²

Level 4: 500÷700 g/m²

Reporting

20 valid results in g/m² for Levels 1, 2 and 3; at least 10 valid results in g/m² for Level 4, if only 10 results can be obtained for Level 4, it is recommended to copy these results to measurement 11-20. Calculate the mean and standard deviation to 3 significant figures.

CEPI test 1.2