DRAINABILITY Schopper-Riegler
Purpose of the test
This test is performed to determine the drainability of a pulp according to the Schopper-Riegler method.
Procedure
Operate the instrument in accordance with ISO 536 and the manufacturer’s instructions.
Soak 24 g of dried pulp (one sheet) at least 4 h in 1200 ml of distilled water at 20°C.
Dilute to 2000 ml with distilled water at 20°C and disintegrate for 30.000 revolutions.
Dilute to about 0,22% a sufficient portion of the disintegrated pulp and determine its concentration by filtering, drying at 105±3°C and weighing.
Wet the drainage chamber with distilled water at 20,0±0,5°C and keep it at such a temperature.
Dilute a volume of the prepared stock containing 2,00±0,02 g of pulp to 1000±5 ml with distilled water at 20,0±0,5°C.
Pour it in the tester and after 5 s release the cone valve.
For everything not specified here refer to ISO 5267-1.
Report 5 measures in SR units, their mean and standard deviation calculated to 3 significant figures.
ISO 5267-1
Nr. of samples
2 test pieces per level
No special size
Levels
Level 1: 15÷25 SR
Level 2: 30÷50 SR
Level 3: 50÷70 SR
Reporting
Report 5 valid results of measurements in SR units, their mean and their standard deviation. All to three significant digits.