AIR PERMEANCE – Gurley

Purpose of the test

This test is performed to determine theair permeance of paper according to Gurley.

Procedure

Operate the instrument in accordance with ISO 5636-5 and the manufacturer’s instructions.

Leave the samples exposed for 24 h to 23°C and 50% R.H., according to ISO 187.

Make a measurement in the middle of each test piece with the marked side turned towards the air flow.

Report 10 measures in s, their mean and standard deviation calculated to 3 significant figures.

ISO 5636-5
Nr. of samples

12 test pieces per level

Special size A4

Levels

Level 1: 35.0÷55.0 s

Level 2: 60.0÷100 s

Level 3: 400÷650 s

Reporting

Report 10 valid results of measurements in s, their mean and their standard deviation. All to three significant digits.

CEPI test 5.4